PROBLEM
- I am trying to print a letter, but I keep getting an error “RPC server is unavailable.”
Full error details:
Unable to cast COM object of type 'Word.ApplicationClass' to interface type 'Word._Application.' This operation failed because the QueryInterface call on the COM component for the interface with ID '{00020970-0000-0000-C000-000000000046}' failed due to the following error: The RPC server is unavailable. (Exception from HRESULT: 0x800706BA)
CAUSE
This happens anytime the Word Process has been ended and Gorilla® is still open.
SOLUTION
The following steps usually correct this problem:
- Close Gorilla. Save and close any open Word documents.
- Open the Task Manager by clicking ctrl + alt + del (if you're connected via RPC try ctrl + shift + esc with the RPC maximized).
- Switch to the Processes tab.
- Locate any WINWORD.exe processes, highlight them and click “End Process.”
- Close the Task Manager.
- Open Gorilla and try printing again.
If you still get the RPC Server error message, restart your computer.